{"id":1294,"date":"2022-07-29T07:48:22","date_gmt":"2022-07-29T07:48:22","guid":{"rendered":"https:\/\/www3.addi-data.com\/?post_type=product&#038;p=1294"},"modified":"2026-04-16T07:27:21","modified_gmt":"2026-04-16T07:27:21","slug":"msx-e1731","status":"publish","type":"product","link":"https:\/\/www.addi-data.com\/de\/product\/msx-e1731","title":{"rendered":"<h1 style=\"font-family: Futura; font-size: 26px;\">MSX-E1721 - Feldbus-DAQ-System - Z\u00e4hleing\u00e4nge<\/h1>"},"content":{"rendered":"<p style=\"font-family: Futura; font-size: 26px; color: #003f81;\">Technische Merkmale<\/p>\n<ul style=\"font-family: Futura; font-size: 16px;\">\n<li>24 V digitaler Triggereingang<\/li>\n<li>ARM \u00ae9 32-Bit Prozessor<\/li>\n<li>64 MB onboard SDRAM zum Speichern der Daten<\/li>\n<li>Robustes, genormtes Metallgeh\u00e4use<\/li>\n<li>Power Save Mode: Reduzierung der Leistungs-\naufnahme, wenn keine Erfassung l\u00e4uft<\/li>\n<\/ul>\n<p style=\"font-family: Futura; font-size: 16px; color: #003f81;\">Sensoreing\u00e4nge<\/p>\n<ul style=\"font-family: Futura; font-size: 16px;\">\n<li>8-pol. M12-Buchsenstecker<\/li>\n<li>4 x EnDat-Z\u00e4hlereing\u00e4nge zur Erfassung von EnDatGebern<\/li>\n<li>Max. Taktfrequenz 4,5 MHzs<\/li>\n<li>Versorgungsspannung der EnDat-Messwertgeber \u00fcber\nM12-Buchse: 5 V \u00b110%<\/li>\n<li>Ausgabe der Werte als Rohwert\noder Positionswert (mm bzw. \u00b0)<\/li>\n<li>Kommunikations-LED f\u00fcr jeden EnDat-Eingang<\/li>\n<\/ul>\n<p style=\"font-family: Futura; font-size: 16px; color: #003f81;\">Sicherheitsmerkmale<\/p>\n<ul style=\"font-family: Futura; font-size: 16px;\">\n<li>LED Statusanzeige f\u00fcr schnelle Fehlerdiagnose<\/li>\n<li>Galvanische Trennung 1000 V<\/li>\n<li>Eingangsfilter<\/li>\n<\/ul>\n<p style=\"font-family: Futura; font-size: 26px; color: #003f81;\">Schnittstellen<\/p>\n<ul style=\"font-family: Futura; font-size: 16px;\">\n<li>Schneller 24 V-Trigger-Eingang<\/li>\n<li>Ethernet-Switch mit 2 Ports<\/li>\n<li>Synchronisation\/trigger In\/Out<\/li>\n<li>Eingang 24 V Versorgung und Kaskadierung<\/li>\n<\/ul>\n<p style=\"font-family: Futura; font-size: 16px; color: #003f81;\">Kommunikationsschnittstellen<\/p>\n<ul style=\"font-family: Futura; font-size: 16px;\">\n<li>Webserver (Konfiguration und Monitoring)<\/li>\n<li>Kommandoserver SOAP f\u00fcr die Zusendung von\nKommandos<\/li>\n<li>Dataserver (TCP\/IP oder UDP-Socket) zur \u00dcbertragung\nder Erfassungswerte<\/li>\n<li>Eventserver (TCP\/IP Socket) zur Zusendung von System-\nevents (Diagnose wie Temperatur, Kurzschluss...)<\/li>\n<li>Kommandoserver Modbus TCP sowie Modbus (UDP) zur\nZusendung von Kommandos<\/li>\n<\/ul>\n<p style=\"font-family: Futura; font-size: 26px; color: #003f81;\">Synchronisation\/Zeitstempel<\/p>\n<p style=\"font-family: Futura; font-size: 16px; color: #003f81;\">Zeitstempel<\/p>\n<p style=\"font-family: Futura; font-size: 16px;\" class=\"translation-block\">\u00dcber einen Synchro-Anschluss k\u00f6nnen mehrere MSX-E-\nSysteme miteinander bis auf 1 \u03bcs synchronisiert werden.\nDadurch ist es m\u00f6glich, auf mehreren MSX-E-Systemen\ngleichzeitig die Datenerfassung zu starten, TriggerEreignisse zu generieren und die Zeit zu synchronisieren.\nAu\u00dferdem verf\u00fcgen die Systeme \u00fcber einen Zeitstempel\n(Time Stamp), der den Zeitpunkt festh\u00e4lt, zu dem die\nDaten vom System erfasst wurden.<\/p>\n<p style=\"font-family: Futura; font-size: 16px;\">Die Kombination zwischen Synchronisierung und\nZeitstempel (TS) erm\u00f6glicht es, Signale, die \u00fcber mehrere\nSysteme erfasst werden, eindeutig zuzuordnen.<\/p>\n<p style=\"font-family: Futura; font-size: 26px; color: #003f81;\">EnDat<\/p>\n<p style=\"font-family: Futura; font-size: 16px;\">EnDat ist ein bidirektionales synchron-serielles Interface f\u00fcr Positionsmessger\u00e4te. Diese Schnittstelle erm\u00f6glicht das Auslesen \nvon absoluten Positionswerten und von Parametern, das Beschreiben von Status- und Initialisierungsregistern und die \n\u00dcbertragung von Zusatzinformationen zum Positionswert. Zus\u00e4tzlich unterst\u00fctzen die EnDat-L\u00f6sungen von ADDI-DATA die \nAuswertung von Diagnose-Werten und den Zugriff auf den OEM-Speicherbereich. Die Daten werden rein seriell \u00fcbertragen.<\/p>\n<ul style=\"font-family: Futura; font-size: 16px;\">\n<li>Schnelle Daten\u00fcbertragung<\/li>\n<li>Signallaufzeitkompensation<\/li>\n<li>Hohe Konturtreue<\/li>\n<li>Hohe \u00dcbertragungssicherheit<\/li>\n<li>Ersparnis zus\u00e4tzlicher Sensorik: Auswertung (Temperatur, Endschalter, etc.)<\/li>\n<li>Serielle \u00dcbertragung: nur 4 Leitungen n\u00f6tig (EnDat 2.2)<\/li>\n<li>Einfache Verdrahtung (M12, 8-polig)<\/li>\n<li>Automatische Parametrierung durch elektronisches Typenschild<\/li>\n<\/ul>\n<p style=\"font-family: Futura; font-size: 26px; color: #003f81;\">Erfassungsmodi<\/p>\n<p style=\"font-family: Futura; font-size: 16px; color: #003f81;\">Asynchrone Erfassung<\/p>\n<p style=\"font-family: Futura; font-size: 16px;\">Bei der asynchronen Erfassung k\u00f6nnen die digitalen Eing\u00e4nge mittels SOAPoder ModbusFunktion ausgelesen werden. Je Funktionsaufruf k\u00f6nnen die\nWerte aller Kan\u00e4le \u00fcbertragen werden.<\/p>\n<p style=\"font-family: Futura; font-size: 16px; color: #003f81;\">Synchrone Erfassung<\/p>\n<p style=\"font-family: Futura; font-size: 16px;\">Bei der synchronen Erfassung werden die Eing\u00e4nge initialisiert und anschlie\u00dfend die Erfassung parametriert. Hier l\u00e4uft die Erfassung in Abh\u00e4ngigkeit\neiner Trigger-Quelle automatisch ab.\nAls Trigger kann entweder der 24V-Triggereingang, ein Synchro-Trigger \noder die Event-Logik verwendet verwendet werden.<\/p>\n<p style=\"font-family: Futura; font-size: 26px; color: #003f81;\">Onboard-Programmierung \/ Stand-alone-Betrieb<\/p>\n<p style=\"font-family: Futura; font-size: 16px; color: #003f81;\">Development Mode<\/p>\n<p style=\"font-family: Futura; font-size: 16px;\">Mit dem Development Mode der MSX-E-Systeme k\u00f6nnen Sie Ihre Mess-, \nSteuer- und Regelapplikationen ma\u00dfgeschneidert an Ihre Bed\u00fcrfnisse \nanpassen. Die geschriebenen Programme laufen direkt auf den MSX-ESystemen. Dies bietet zwei Vorteile: externe PCs werden entlastet und Sie \nk\u00f6nnen die erfassten Daten frei nach Ihrem Bedarf verarbeiten. Sie steigern \ndamit die Effizienz Ihrer Prozesse und sichern gleichzeitig Ihre Investitionen<\/p>\n<p style=\"font-family: Futura; font-size: 26px; color: #003f81;\">ConfigTools<\/p>\n<p style=\"font-family: Futura; font-size: 16px;\" class=\"translation-block\">Das Programm ConfigTools erm\u00f6glicht es, die MSX-E-Systeme einfach zu \nverwalten. Diese werden automatisch im Netzwerk erkannt. ConfigTools\nbesteht aus gemeinsamen und spezifischen Funktionen.\nMit ConfigTools kann zus\u00e4tzlich die komplette Konfiguration eines MSX-ESystems gespeichert und auf ein weiteres System desselben Typs \u00fcbertragen \nwerden (Clone-Funktion).\nConfigTools ist im Lieferumfang enthalten.<\/p>\n<p style=\"font-family: Futura; font-size: 16px; color: #003f81;\">ConfigTools-Funktionen f\u00fcr MSX-E3011:<\/p>\n<ul style=\"font-family: Futura; font-size: 16px;\">\n<li>IP-Adresse \u00e4ndern<\/li>\n<li>Weboberfl\u00e4che anzeigen<\/li>\n<li>Firmware-Aktualisierung<\/li>\n<li>Systemkonfiguration speichern\/laden<\/li>\n<li>Kanalkonfiguration speichern\/laden<\/li>\n<li>Monitor f\u00fcr analoge Eing\u00e4nge<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p style=\"font-family: Futura; font-size: 16px;\">The\u00a0<strong>Ethernet\u00a0EnDat counter system MSX-E1731<\/strong>\u00a0has\u00a0<strong>4 EnDat 2.2 inputs with status LEDs<\/strong>,\u00a0<strong>16 digital I\/O<\/strong>, 24 V, and\u00a0<strong>a 24 V trigger input<\/strong>. The system was especially developed for the acquisition of sensor- and actuator data close to the sensor in the\u00a0<strong>harsh industrial environment<\/strong>\u00a0and has\u00a0 a robust normed metal housing with the\u00a0<strong>degree of protection IP 65<\/strong>. It has an extended temperature range from\u00a0<strong>-40\u00b0C to +85\u00b0C<\/strong>. The ARM\u00ae9 32-bit processor allows the calculation of the acquired values. The Development Mode allows to customise applications individually. Through synchro connection, several MSX-E systems can be cascaed and synchronised with one another in the \u00b5s range.<\/p>\n[su_button url=\"https:\/\/www.addi-data.com\/formproduct?product_page=MSX-E1731\" style=\"glass\" background=\"#9b2e41\" size=\"5\" icon=\"icon: tags\" icon_color=\"#ffffff\" text_shadow=\"0px 0px 0px #000000\"]Get a quote[\/su_button]\n","protected":false},"featured_media":1010,"template":"","meta":{"content-type":""},"product_brand":[],"product_cat":[178],"product_tag":[],"class_list":{"0":"post-1294","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-msx-e-system-counting-inputs","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple","12":"prodpage-classic"},"yoast_head":"\n<title>MSX-E1731 - Fieldbus DAQ System - Counting Inputs<\/title>\n<meta name=\"description\" content=\"The\u00a0Ethernet\u00a0EnDat counter system MSX-E1731\u00a0has\u00a04 EnDat 2.2 inputs with status LEDs,\u00a016 digital I\/O, 24 V, and\u00a0a 24 V trigger input.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.addi-data.com\/de\/produkt\/msx-e1731\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"MSX-E1731 - Fieldbus DAQ System - Counting Inputs\" \/>\n<meta property=\"og:description\" content=\"The\u00a0Ethernet\u00a0EnDat counter system MSX-E1731\u00a0has\u00a04 EnDat 2.2 inputs with status LEDs,\u00a016 digital I\/O, 24 V, and\u00a0a 24 V trigger input.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.addi-data.com\/de\/produkt\/msx-e1731\/\" \/>\n<meta property=\"og:site_name\" content=\"ADDI-DATA\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-16T07:27:21+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.addi-data.com\/wp-content\/uploads\/2022\/06\/Pressebild_MSX-E1731-72dpi.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"500\" \/>\n\t<meta property=\"og:image:height\" content=\"343\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data1\" content=\"1\u00a0Minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.addi-data.com\\\/product\\\/msx-e1731\",\"url\":\"https:\\\/\\\/www.addi-data.com\\\/product\\\/msx-e1731\",\"name\":\"MSX-E1731 - Fieldbus DAQ System - Counting Inputs\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.addi-data.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.addi-data.com\\\/product\\\/msx-e1731#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.addi-data.com\\\/product\\\/msx-e1731#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.addi-data.com\\\/wp-content\\\/uploads\\\/2022\\\/06\\\/Pressebild_MSX-E1731-72dpi.jpg\",\"datePublished\":\"2022-07-29T07:48:22+00:00\",\"dateModified\":\"2026-04-16T07:27:21+00:00\",\"description\":\"The\u00a0Ethernet\u00a0EnDat counter system MSX-E1731\u00a0has\u00a04 EnDat 2.2 inputs with status LEDs,\u00a016 digital I\\\/O, 24 V, and\u00a0a 24 V trigger input.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.addi-data.com\\\/product\\\/msx-e1731#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.addi-data.com\\\/product\\\/msx-e1731\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/www.addi-data.com\\\/product\\\/msx-e1731#primaryimage\",\"url\":\"https:\\\/\\\/www.addi-data.com\\\/wp-content\\\/uploads\\\/2022\\\/06\\\/Pressebild_MSX-E1731-72dpi.jpg\",\"contentUrl\":\"https:\\\/\\\/www.addi-data.com\\\/wp-content\\\/uploads\\\/2022\\\/06\\\/Pressebild_MSX-E1731-72dpi.jpg\",\"width\":500,\"height\":343,\"caption\":\"fieldbus system MSX-E1731\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.addi-data.com\\\/product\\\/msx-e1731#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.addi-data.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\\\/\\\/www.addi-data.com\\\/test\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"MSX-E1731 &#8211; Fieldbus DAQ System &#8211; Counting Inputs\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.addi-data.com\\\/#website\",\"url\":\"https:\\\/\\\/www.addi-data.com\\\/\",\"name\":\"ADDI-DATA\",\"description\":\"Discover powerful high-tech products for industrial measurement and automation.\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.addi-data.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.addi-data.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.addi-data.com\\\/#organization\",\"name\":\"ADDI-DATA\",\"url\":\"https:\\\/\\\/www.addi-data.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/www.addi-data.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www3.addi-data.com\\\/wp-content\\\/uploads\\\/2022\\\/05\\\/addi_data_spirit_of_excellence_PETIT_COULEURS_2021.png\",\"contentUrl\":\"https:\\\/\\\/www3.addi-data.com\\\/wp-content\\\/uploads\\\/2022\\\/05\\\/addi_data_spirit_of_excellence_PETIT_COULEURS_2021.png\",\"width\":786,\"height\":211,\"caption\":\"ADDI-DATA\"},\"image\":{\"@id\":\"https:\\\/\\\/www.addi-data.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/addi-data\\\/\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCM2yhuO7z5Jpe9KRgg8HsRw\\\/videos\"]}]}<\/script>\n","yoast_head_json":{"title":"MSX-E1721 - Feldbus-DAQ-System - Z\u00e4hleing\u00e4nge","description":"The\u00a0Ethernet\u00a0EnDat counter system MSX-E1731\u00a0has\u00a04 EnDat 2.2 inputs with status LEDs,\u00a016 digital I\/O, 24 V, and\u00a0a 24 V trigger input.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.addi-data.com\/de\/produkt\/msx-e1731\/","og_locale":"de_DE","og_type":"article","og_title":"MSX-E1731 - Fieldbus DAQ System - Counting Inputs","og_description":"The\u00a0Ethernet\u00a0EnDat counter system MSX-E1731\u00a0has\u00a04 EnDat 2.2 inputs with status LEDs,\u00a016 digital I\/O, 24 V, and\u00a0a 24 V trigger input.","og_url":"https:\/\/www.addi-data.com\/de\/produkt\/msx-e1731\/","og_site_name":"ADDI-DATA","article_modified_time":"2026-04-16T07:27:21+00:00","og_image":[{"width":500,"height":343,"url":"https:\/\/www.addi-data.com\/wp-content\/uploads\/2022\/06\/Pressebild_MSX-E1731-72dpi.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Gesch\u00e4tzte Lesezeit":"1\u00a0Minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.addi-data.com\/product\/msx-e1731","url":"https:\/\/www.addi-data.com\/product\/msx-e1731","name":"MSX-E1721 - Feldbus-DAQ-System - Z\u00e4hleing\u00e4nge","isPartOf":{"@id":"https:\/\/www.addi-data.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.addi-data.com\/product\/msx-e1731#primaryimage"},"image":{"@id":"https:\/\/www.addi-data.com\/product\/msx-e1731#primaryimage"},"thumbnailUrl":"https:\/\/www.addi-data.com\/wp-content\/uploads\/2022\/06\/Pressebild_MSX-E1731-72dpi.jpg","datePublished":"2022-07-29T07:48:22+00:00","dateModified":"2026-04-16T07:27:21+00:00","description":"The\u00a0Ethernet\u00a0EnDat counter system MSX-E1731\u00a0has\u00a04 EnDat 2.2 inputs with status LEDs,\u00a016 digital I\/O, 24 V, and\u00a0a 24 V trigger input.","breadcrumb":{"@id":"https:\/\/www.addi-data.com\/product\/msx-e1731#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.addi-data.com\/product\/msx-e1731"]}]},{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.addi-data.com\/product\/msx-e1731#primaryimage","url":"https:\/\/www.addi-data.com\/wp-content\/uploads\/2022\/06\/Pressebild_MSX-E1731-72dpi.jpg","contentUrl":"https:\/\/www.addi-data.com\/wp-content\/uploads\/2022\/06\/Pressebild_MSX-E1731-72dpi.jpg","width":500,"height":343,"caption":"fieldbus system MSX-E1731"},{"@type":"BreadcrumbList","@id":"https:\/\/www.addi-data.com\/product\/msx-e1731#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.addi-data.com\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/www.addi-data.com\/test"},{"@type":"ListItem","position":3,"name":"MSX-E1731 &#8211; Fieldbus DAQ System &#8211; Counting Inputs"}]},{"@type":"WebSite","@id":"https:\/\/www.addi-data.com\/#website","url":"https:\/\/www.addi-data.com\/","name":"ADDI-DATA","description":"Entdecken Sie leistungsstarke Hightech-Produkte f\u00fcr die industrielle Messung und Automatisierung.","publisher":{"@id":"https:\/\/www.addi-data.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.addi-data.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https:\/\/www.addi-data.com\/#organization","name":"ADDI-DATA","url":"https:\/\/www.addi-data.com\/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.addi-data.com\/#\/schema\/logo\/image\/","url":"https:\/\/www3.addi-data.com\/wp-content\/uploads\/2022\/05\/addi_data_spirit_of_excellence_PETIT_COULEURS_2021.png","contentUrl":"https:\/\/www3.addi-data.com\/wp-content\/uploads\/2022\/05\/addi_data_spirit_of_excellence_PETIT_COULEURS_2021.png","width":786,"height":211,"caption":"ADDI-DATA"},"image":{"@id":"https:\/\/www.addi-data.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/addi-data\/","https:\/\/www.youtube.com\/channel\/UCM2yhuO7z5Jpe9KRgg8HsRw\/videos"]}]}},"_links":{"self":[{"href":"https:\/\/www.addi-data.com\/de\/wp-json\/wp\/v2\/product\/1294","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.addi-data.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.addi-data.com\/de\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.addi-data.com\/de\/wp-json\/wp\/v2\/media\/1010"}],"wp:attachment":[{"href":"https:\/\/www.addi-data.com\/de\/wp-json\/wp\/v2\/media?parent=1294"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.addi-data.com\/de\/wp-json\/wp\/v2\/product_brand?post=1294"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.addi-data.com\/de\/wp-json\/wp\/v2\/product_cat?post=1294"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.addi-data.com\/de\/wp-json\/wp\/v2\/product_tag?post=1294"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}<!-- This website is optimized by Airlift. Learn more: https://airlift.net. Template:. Learn more: https://airlift.net. Template: 69f2276f190636c9eedfd830. Config Timestamp: 2026-04-29 15:44:46 UTC, Cached Timestamp: 2026-05-01 23:08:13 UTC -->