{"id":1284,"date":"2022-07-29T06:43:43","date_gmt":"2022-07-29T06:43:43","guid":{"rendered":"https:\/\/www3.addi-data.com\/?post_type=product&#038;p=1284"},"modified":"2026-04-16T07:20:16","modified_gmt":"2026-04-16T07:20:16","slug":"msx-e3511","status":"publish","type":"product","link":"https:\/\/www.addi-data.com\/pl\/product\/msx-e3511","title":{"rendered":"<h1 style=\"font-family: Futura; font-size: 26px;\">MSX-E3511 &#8211; Fieldbus DAQ System &#8211; Analog Outputs<\/h1>"},"content":{"rendered":"<p style=\"font-family: Futura; font-size: 26px; color: #003f81;\">Features<\/p>\n<ul style=\"font-family: Futura; font-size: 16px;\">\n<li>24 V digital trigger input<\/li>\n<li>ARM\u00ae9 32-bit processor<\/li>\n<li>64 MB onboard SDRAM for storing data<\/li>\n<li>Robust standardized metal housing<\/li>\n<li>Power Save Mode: Reduced power consumption when no acquisition runs<\/li>\n<\/ul>\n<p style=\"font-family: Futura; font-size: 16px; color: #003f81;\">Analog outputs<\/p>\n<ul style=\"font-family: Futura; font-size: 16px;\">\n<li class=\"translation-block\">8 analog outputs, 16-bit:<br>\r\nMSX-E3511: voltage outputs 0-10 V, \u00b1 10 V<br>\r\nMSX-E3511-C: each output can be configured as voltage or current output 0-20 mA<\/li>\n<li>Output voltage after reset 0 V<\/li>\n<li>5-pin M12 female connector*<\/li>\n<li>Output mode\/operation mode: Data output per software function, trigger input or synchro output<\/li>\n<\/ul>\n<p style=\"font-family: Futura; font-size: 16px; color: #003f81;\">Function generator<\/p>\n<ul style=\"font-family: Futura; font-size: 16px;\">\n<li>Output of any signal type, e. g. sine curves, sawtooth curves etc<\/li>\n<li>Maximal 8 channels (each channel independently)<\/li>\n<li>Can be used without programming skills, e. g. via .csvfile or mathematic functions such as \u0192(x) = sin(x)<\/li>\n<\/ul>\n<p style=\"font-family: Futura; font-size: 16px; color: #003f81;\">Safety features<\/p>\n<ul style=\"font-family: Futura; font-size: 16px;\">\n<li>Status LEDs for fast error diagnostics<\/li>\n<li>Optical isolation<\/li>\n<li>Diagnostics in case of short-circuits (voltage mode) or line break (current mode)<\/li>\n<li>Internal temperature monitoring<\/li>\n<\/ul>\n<p style=\"font-family: Futura; font-size: 26px; color: #003f81;\">Interfaces<\/p>\n<ul style=\"font-family: Futura; font-size: 16px;\">\n<li>Fast 24 V trigger input<\/li>\n<li>Ethernet switch with 2 ports<\/li>\n<li>Synchronisation\/trigger In\/Out<\/li>\n<li>Line in for 24 V supply and cascading<\/li>\n<\/ul>\n<p style=\"font-family: Futura; font-size: 16px; color: #003f81;\">Communication interfaces<\/p>\n<ul style=\"font-family: Futura; font-size: 16px;\">\n<li>Web server (configuration and monitoring)<\/li>\n<li>Command server SOAP for transferring commands<\/li>\n<li>Data server (TCP\/IP or UDP socket) for sending acquisition data<\/li>\n<li>Event server (TCP\/IP socket) for sending system events (Diagnostics such as temperature, short-circuits &#8230;)<\/li>\n<li>Command server Modbus TCP and Modbus (UDP) for sending commands<\/li>\n<\/ul>\n<p style=\"font-family: Futura; font-size: 26px; color: #003f81;\">Synchronisation\/time stamp<\/p>\n<p style=\"font-family: Futura; font-size: 16px; color: #003f81;\">Time stamp<\/p>\n<p style=\"font-family: Futura; font-size: 16px;\" class=\"translation-block\">Several MSX-E systems can be synchronised with one another in the \u00b5s range through a synchro connection. This allows to start a synchronous data acquisition, to<br>\r\ngenerate trigger events and to synchronise the time on several MSX-E systems. Furthermore, the systems have a time stamp that logs the point in time at which the data was acquired by the system.<\/p>\n<p style=\"font-family: Futura; font-size: 16px;\">The combination of synchronisation and time stamp (TS) allows the clear allocation of signals that were captured by several systems.<\/p>\n<p style=\"font-family: Futura; font-size: 26px; color: #003f81;\">Output modes<\/p>\n<p style=\"font-family: Futura; font-size: 16px; color: #003f81;\">Direct access<\/p>\n<p style=\"font-family: Futura; font-size: 16px;\">In direct access, the values of the outputs are transmitted via SOAP or Modbus function. For each function call, 1 value (for one or several outputs) is sent. The value output is triggered per software, 24V hardware or synchro trigger.<\/p>\n<p style=\"font-family: Futura; font-size: 16px; color: #003f81;\">Function generator<\/p>\n<p style=\"font-family: Futura; font-size: 16px;\">The MSX-E3511 system features a function generator for each analog output. The values are sent either automatically at a defined rate or using a trigger. The 24V trigger input or the synchro trigger can be used, included those issued by another MSX-E system.<\/p>\n<p style=\"font-family: Futura; font-size: 26px; color: #003f81;\">Onboard programming \/ stand-alone operation<\/p>\n<p style=\"font-family: Futura; font-size: 16px; color: #003f81;\">Development mode<\/p>\n<p style=\"font-family: Futura; font-size: 16px;\">With the Development mode of the MSX-E systems you can customise your measurement, control and regulation applications to fit your requirements. The programs run directly on the MSX-E systems, which has two advantages: external PCs are relieved and you can process data freely according to your requirements. This helps you to improve the efficiency of your processes and to secure your investments.<\/p>\n<p style=\"font-family: Futura; font-size: 26px; color: #003f81;\">Safety<\/p>\n<p style=\"font-family: Futura; font-size: 16px; color: #003f81;\">Watchdog<\/p>\n<p style=\"font-family: Futura; font-size: 16px;\">The MSX-E3511 Ethernet system has a 16-bit watchdog which can be programmed in 3 time units (\u00b5s, ms, s). The watchdog is used for automatically resetting the digital outputs to 0 V after a defined time in order e. g. to switch off actuators if an error has occurred.<\/p>\n<p style=\"font-family: Futura; font-size: 26px; color: #003f81;\">ConfigTools<\/p>\n<p style=\"font-family: Futura; font-size: 16px;\" class=\"translation-block\">The ConfigTools program allows an easy administration of the MSX-E systems. These are automatically detected in the network. ConfigTools<br>\r\nconsists of common and specific functions. In addition, with ConfigTools, the complete configuration of a MSX-E system can be saved and transferred to another system of the same type (clone function). ConfigTools is included in the delivery<\/p>\n<p style=\"font-family: Futura; font-size: 16px; color: #003f81;\">ConfigTools functions for MSX-E3011:<\/p>\n<ul style=\"font-family: Futura; font-size: 16px;\">\n<li>Change of IP address<\/li>\n<li>Display of web interface<\/li>\n<li>Firmware update<\/li>\n<li>Save\/load system configuration<\/li>\n<li>Save\/load channel configuration<\/li>\n<li>Monitor for analog inputs<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p style=\"font-family: Futura; font-size: 16px;\">The\u00a0<strong>Ethernet analog output system MSX-E3511<\/strong>\u00a0has\u00a0<strong>8 analog outputs<\/strong>, 16-bit. It is available in\u00a0<strong>2 versions<\/strong>:\u00a0<strong>MSX-E3511 with voltage outputs<\/strong>\u00a0or\u00a0<strong>MSX-E3511-C with outputs that can be set as voltage or current outputs<\/strong>. The system has a 24 V trigger input and a\u00a0<strong>function generator<\/strong>, that allows the output of any signal type, e. g. sine curves, sawtooth curves etc., the signal type can be configurated separately for each channel. It has a robust normed metal housing with the\u00a0<strong>degree of protection IP 65\u00a0<\/strong>and an extended temperature range from\u00a0<strong>-40\u00b0C to +85\u00b0C<\/strong>. The ARM\u00ae9 32-bit processor allows the calculation of the acquired values. The Development Mode allows to customise applications individually. Through synchro connection, several MSX-E systems can be daisy-chained and synchronised with one another in the \u00b5s range.<\/p>\n[su_button url=\"https:\/\/www.addi-data.com\/formproduct?product_page=MSX-E3511\" style=\"glass\" background=\"#9b2e41\" size=\"5\" icon=\"icon: tags\" icon_color=\"#ffffff\" text_shadow=\"0px 0px 0px #000000\"]Get a quote[\/su_button]\n","protected":false},"featured_media":1022,"template":"","meta":{"content-type":""},"product_brand":[],"product_cat":[173],"product_tag":[],"class_list":["post-1284","product","type-product","status-publish","has-post-thumbnail","product_cat-msx-e-system-analog-outputs","first","instock","shipping-taxable","product-type-simple","prodpage-classic"],"yoast_head":"\n<title>MSX-E3511 - Fieldbus DAQ System - Analog Outputs<\/title>\n<meta name=\"description\" content=\"The\u00a0Ethernet analog output system MSX-E3511\u00a0has\u00a08 analog outputs, 16-bit. It is available in\u00a02 versions:\u00a0MSX-E3511 with voltage outputs\u00a0or\u00a0MSX-E3511-C with outputs that can be set as voltage or current outputs.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.addi-data.com\/pl\/product\/msx-e3511\/\" \/>\n<meta property=\"og:locale\" content=\"pl_PL\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"MSX-E3511 - Fieldbus DAQ System - Analog Outputs\" \/>\n<meta property=\"og:description\" content=\"The\u00a0Ethernet analog output system MSX-E3511\u00a0has\u00a08 analog outputs, 16-bit. It is available in\u00a02 versions:\u00a0MSX-E3511 with voltage outputs\u00a0or\u00a0MSX-E3511-C with outputs that can be set as voltage or current outputs.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.addi-data.com\/pl\/product\/msx-e3511\/\" \/>\n<meta property=\"og:site_name\" content=\"ADDI-DATA\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-16T07:20:16+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.addi-data.com\/wp-content\/uploads\/2022\/06\/MSX-E3511_h252.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"300\" \/>\n\t<meta property=\"og:image:height\" content=\"252\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Szacowany czas czytania\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minuta\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.addi-data.com\\\/product\\\/msx-e3511\",\"url\":\"https:\\\/\\\/www.addi-data.com\\\/product\\\/msx-e3511\",\"name\":\"MSX-E3511 - Fieldbus DAQ System - Analog Outputs\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.addi-data.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.addi-data.com\\\/product\\\/msx-e3511#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.addi-data.com\\\/product\\\/msx-e3511#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.addi-data.com\\\/wp-content\\\/uploads\\\/2022\\\/06\\\/MSX-E3511_h252.jpg\",\"datePublished\":\"2022-07-29T06:43:43+00:00\",\"dateModified\":\"2026-04-16T07:20:16+00:00\",\"description\":\"The\u00a0Ethernet analog output system MSX-E3511\u00a0has\u00a08 analog outputs, 16-bit. It is available in\u00a02 versions:\u00a0MSX-E3511 with voltage outputs\u00a0or\u00a0MSX-E3511-C with outputs that can be set as voltage or current outputs.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.addi-data.com\\\/product\\\/msx-e3511#breadcrumb\"},\"inLanguage\":\"pl-PL\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.addi-data.com\\\/product\\\/msx-e3511\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"pl-PL\",\"@id\":\"https:\\\/\\\/www.addi-data.com\\\/product\\\/msx-e3511#primaryimage\",\"url\":\"https:\\\/\\\/www.addi-data.com\\\/wp-content\\\/uploads\\\/2022\\\/06\\\/MSX-E3511_h252.jpg\",\"contentUrl\":\"https:\\\/\\\/www.addi-data.com\\\/wp-content\\\/uploads\\\/2022\\\/06\\\/MSX-E3511_h252.jpg\",\"width\":300,\"height\":252,\"caption\":\"fieldbus system MSX-E3511\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.addi-data.com\\\/product\\\/msx-e3511#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.addi-data.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\\\/\\\/www.addi-data.com\\\/test\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"MSX-E3511 &#8211; Fieldbus DAQ System &#8211; Analog Outputs\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.addi-data.com\\\/#website\",\"url\":\"https:\\\/\\\/www.addi-data.com\\\/\",\"name\":\"ADDI-DATA\",\"description\":\"Discover powerful high-tech products for industrial measurement and automation.\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.addi-data.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.addi-data.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"pl-PL\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.addi-data.com\\\/#organization\",\"name\":\"ADDI-DATA\",\"url\":\"https:\\\/\\\/www.addi-data.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pl-PL\",\"@id\":\"https:\\\/\\\/www.addi-data.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www3.addi-data.com\\\/wp-content\\\/uploads\\\/2022\\\/05\\\/addi_data_spirit_of_excellence_PETIT_COULEURS_2021.png\",\"contentUrl\":\"https:\\\/\\\/www3.addi-data.com\\\/wp-content\\\/uploads\\\/2022\\\/05\\\/addi_data_spirit_of_excellence_PETIT_COULEURS_2021.png\",\"width\":786,\"height\":211,\"caption\":\"ADDI-DATA\"},\"image\":{\"@id\":\"https:\\\/\\\/www.addi-data.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/addi-data\\\/\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCM2yhuO7z5Jpe9KRgg8HsRw\\\/videos\"]}]}<\/script>\n","yoast_head_json":{"title":"MSX-E3511 - Fieldbus DAQ System - Analog Outputs","description":"The\u00a0Ethernet analog output system MSX-E3511\u00a0has\u00a08 analog outputs, 16-bit. It is available in\u00a02 versions:\u00a0MSX-E3511 with voltage outputs\u00a0or\u00a0MSX-E3511-C with outputs that can be set as voltage or current outputs.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.addi-data.com\/pl\/product\/msx-e3511\/","og_locale":"pl_PL","og_type":"article","og_title":"MSX-E3511 - Fieldbus DAQ System - Analog Outputs","og_description":"The\u00a0Ethernet analog output system MSX-E3511\u00a0has\u00a08 analog outputs, 16-bit. It is available in\u00a02 versions:\u00a0MSX-E3511 with voltage outputs\u00a0or\u00a0MSX-E3511-C with outputs that can be set as voltage or current outputs.","og_url":"https:\/\/www.addi-data.com\/pl\/product\/msx-e3511\/","og_site_name":"ADDI-DATA","article_modified_time":"2026-04-16T07:20:16+00:00","og_image":[{"width":300,"height":252,"url":"https:\/\/www.addi-data.com\/wp-content\/uploads\/2022\/06\/MSX-E3511_h252.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Szacowany czas czytania":"1 minuta"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.addi-data.com\/product\/msx-e3511","url":"https:\/\/www.addi-data.com\/product\/msx-e3511","name":"MSX-E3511 - Fieldbus DAQ System - Analog Outputs","isPartOf":{"@id":"https:\/\/www.addi-data.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.addi-data.com\/product\/msx-e3511#primaryimage"},"image":{"@id":"https:\/\/www.addi-data.com\/product\/msx-e3511#primaryimage"},"thumbnailUrl":"https:\/\/www.addi-data.com\/wp-content\/uploads\/2022\/06\/MSX-E3511_h252.jpg","datePublished":"2022-07-29T06:43:43+00:00","dateModified":"2026-04-16T07:20:16+00:00","description":"The\u00a0Ethernet analog output system MSX-E3511\u00a0has\u00a08 analog outputs, 16-bit. It is available in\u00a02 versions:\u00a0MSX-E3511 with voltage outputs\u00a0or\u00a0MSX-E3511-C with outputs that can be set as voltage or current outputs.","breadcrumb":{"@id":"https:\/\/www.addi-data.com\/product\/msx-e3511#breadcrumb"},"inLanguage":"pl-PL","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.addi-data.com\/product\/msx-e3511"]}]},{"@type":"ImageObject","inLanguage":"pl-PL","@id":"https:\/\/www.addi-data.com\/product\/msx-e3511#primaryimage","url":"https:\/\/www.addi-data.com\/wp-content\/uploads\/2022\/06\/MSX-E3511_h252.jpg","contentUrl":"https:\/\/www.addi-data.com\/wp-content\/uploads\/2022\/06\/MSX-E3511_h252.jpg","width":300,"height":252,"caption":"fieldbus system MSX-E3511"},{"@type":"BreadcrumbList","@id":"https:\/\/www.addi-data.com\/product\/msx-e3511#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.addi-data.com\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/www.addi-data.com\/test"},{"@type":"ListItem","position":3,"name":"MSX-E3511 &#8211; Fieldbus DAQ System &#8211; Analog Outputs"}]},{"@type":"WebSite","@id":"https:\/\/www.addi-data.com\/#website","url":"https:\/\/www.addi-data.com\/","name":"ADDI-DATA","description":"Discover powerful high-tech products for industrial measurement and automation.","publisher":{"@id":"https:\/\/www.addi-data.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.addi-data.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pl-PL"},{"@type":"Organization","@id":"https:\/\/www.addi-data.com\/#organization","name":"ADDI-DATA","url":"https:\/\/www.addi-data.com\/","logo":{"@type":"ImageObject","inLanguage":"pl-PL","@id":"https:\/\/www.addi-data.com\/#\/schema\/logo\/image\/","url":"https:\/\/www3.addi-data.com\/wp-content\/uploads\/2022\/05\/addi_data_spirit_of_excellence_PETIT_COULEURS_2021.png","contentUrl":"https:\/\/www3.addi-data.com\/wp-content\/uploads\/2022\/05\/addi_data_spirit_of_excellence_PETIT_COULEURS_2021.png","width":786,"height":211,"caption":"ADDI-DATA"},"image":{"@id":"https:\/\/www.addi-data.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/addi-data\/","https:\/\/www.youtube.com\/channel\/UCM2yhuO7z5Jpe9KRgg8HsRw\/videos"]}]}},"_links":{"self":[{"href":"https:\/\/www.addi-data.com\/pl\/wp-json\/wp\/v2\/product\/1284","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.addi-data.com\/pl\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.addi-data.com\/pl\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.addi-data.com\/pl\/wp-json\/wp\/v2\/media\/1022"}],"wp:attachment":[{"href":"https:\/\/www.addi-data.com\/pl\/wp-json\/wp\/v2\/media?parent=1284"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.addi-data.com\/pl\/wp-json\/wp\/v2\/product_brand?post=1284"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.addi-data.com\/pl\/wp-json\/wp\/v2\/product_cat?post=1284"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.addi-data.com\/pl\/wp-json\/wp\/v2\/product_tag?post=1284"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}<!-- This website is optimized by Airlift. Learn more: https://airlift.net. Template:. Learn more: https://airlift.net. Template: 6a1da9131906363e1d0290a4. Config Timestamp: 2026-06-01 15:45:22 UTC, Cached Timestamp: 2026-06-14 04:37:02 UTC -->