{"id":1285,"date":"2022-07-29T07:05:49","date_gmt":"2022-07-29T07:05:49","guid":{"rendered":"https:\/\/www3.addi-data.com\/?post_type=product&#038;p=1285"},"modified":"2026-04-16T07:21:02","modified_gmt":"2026-04-16T07:21:02","slug":"msx-e3211","status":"publish","type":"product","link":"https:\/\/www.addi-data.com\/pl\/product\/msx-e3211","title":{"rendered":"<h1 style=\"font-family: Futura; font-size: 26px;\">MSX-E3211 &#8211; Fieldbus DAQ System &#8211; Temperature measurement<\/h1>"},"content":{"rendered":"<p style=\"font-family: Futura; font-size: 26px; color: #003f81;\">Features<\/p>\n<ul style=\"font-family: Futura; font-size: 16px;\">\n<li>24 V digital trigger input<\/li>\n<li>ARM\u00ae9 32-bit processor<\/li>\n<li>64 MB onboard SDRAM for storing data<\/li>\n<li>Robust standardized metal housing<\/li>\n<li>Power Save Mode: Reduced power consumption when no acquisition runs<\/li>\n<\/ul>\n<p style=\"font-family: Futura; font-size: 16px; color: #003f81;\">Temperature inputs<\/p>\n<ul style=\"font-family: Futura; font-size: 16px;\">\n<li>16\/8\/4 differential inputs for thermocouples or RTD, 24-bit<\/li>\n<li>Sampling frequency max. 788 Hz\/channel (max. 8\/4\/2 channels simultaneously)<\/li>\n<li>Auto gain: Optimal adjustment of the gain to the measuring range<\/li>\n<li>Integrated cold junction compensation (CJC) for thermocouples<\/li>\n<li>NTC sensors optional<\/li>\n<\/ul>\n<p style=\"font-family: Futura; font-size: 16px; color: #003f81;\">Safety features<\/p>\n<ul style=\"font-family: Futura; font-size: 16px;\">\n<li>Status LEDs for fast error diagnostics<\/li>\n<li>Optical isolation<\/li>\n<li>\u00a0Input filters<\/li>\n<\/ul>\n<p style=\"font-family: Futura; font-size: 26px; color: #003f81;\">Interfaces<\/p>\n<ul style=\"font-family: Futura; font-size: 16px;\">\n<li>Fast 24 V trigger input<\/li>\n<li>Ethernet switch with 2 ports<\/li>\n<li>Synchronisation\/trigger In\/Out<\/li>\n<li>Line in for 24 V supply and cascading<\/li>\n<\/ul>\n<p style=\"font-family: Futura; font-size: 16px; color: #003f81;\">Communication interfaces<\/p>\n<ul style=\"font-family: Futura; font-size: 16px;\">\n<li>Web server (configuration and monitoring)<\/li>\n<li>Command server SOAP for transferring commands<\/li>\n<li>Data server (TCP\/IP or UDP socket) for sending acquisition data<\/li>\n<li>Event server (TCP\/IP socket) for sending system events (Diagnostics such as temperature, short-circuits &#8230;)<\/li>\n<li>Command server Modbus TCP and Modbus (UDP) for sending commands<\/li>\n<\/ul>\n<p style=\"font-family: Futura; font-size: 26px; color: #003f81;\">Synchronisation\/time stamp<\/p>\n<p style=\"font-family: Futura; font-size: 16px; color: #003f81;\">Time stamp<\/p>\n<p style=\"font-family: Futura; font-size: 16px;\" class=\"translation-block\">Several MSX-E systems can be synchronised with one another in the \u00b5s range through a synchro connection. This allows to start a synchronous data acquisition, to<br>\r\ngenerate trigger events and to synchronise the time on several MSX-E systems. Furthermore, the systems have a time stamp that logs the point in time at which the data was acquired by the system.<\/p>\n<p style=\"font-family: Futura; font-size: 16px;\">The combination of synchronisation and time stamp (TS) allows the clear allocation of signals that were captured by several systems.<\/p>\n<p style=\"font-family: Futura; font-size: 26px; color: #003f81;\">Acquisition modes<\/p>\n<p style=\"font-family: Futura; font-size: 16px; color: #003f81;\">Auto-refresh mode<\/p>\n<p style=\"font-family: Futura; font-size: 16px;\" class=\"translation-block\">In auto-refresh mode, the measurement values are updated automatically after each acquisition. The acquisition is initialised once and the values of<br>\r\nthe channels are stored in the memory of the MSX-E Ethernet system. The client (e.g. PC, server, PLC, \u2026) reads the acquired values asynchronously to the acquisition through socket connection, SOAP or Modbus function. Thereby, the new value is read and the old values are overwritten. In addition to the measurement values, the auto-refresh counter can also be read, which allows to sort the measurement values chronologically. The auto-refresh mode can be combined with a hardware or a synchro trigger and also allows the automatic averaging of values.<\/p>\n<p style=\"font-family: Futura; font-size: 16px; color: #003f81;\">Sequence mode<\/p>\n<p style=\"font-family: Futura; font-size: 16px;\">In sequence mode, a list of channels is acquired. Thereby, the single measurement rows are stored one after another. The client receives the acquired values asynchronously to the acquisition through a socket connection. In the sequence mode, the measurement values are read in chronological order, this means the oldest values are read first. The acquisition can be effected continuously, with or without delay or in combination with a hardware or synchro trigger<\/p>\n<p style=\"font-family: Futura; font-size: 26px; color: #003f81;\">Onboard programming \/ stand-alone operation<\/p>\n<p style=\"font-family: Futura; font-size: 16px; color: #003f81;\">Development mode<\/p>\n<p style=\"font-family: Futura; font-size: 16px;\">With the Development mode of the MSX-E systems you can customise your measurement, control and regulation applications to fit your requirements. The programs run directly on the MSX-E systems, which has two advantages: external PCs are relieved and you can process data freely according to your requirements. This helps you to improve the efficiency of your processes and to secure your investments.<\/p>\n<p style=\"font-family: Futura; font-size: 26px; color: #003f81;\">ConfigTools<\/p>\n<p style=\"font-family: Futura; font-size: 16px;\" class=\"translation-block\">The ConfigTools program allows an easy administration of the MSX-E systems. These are automatically detected in the network. ConfigTools<br>\r\nconsists of common and specific functions. In addition, with ConfigTools, the complete configuration of a MSX-E system can be saved and transferred to another system of the same type (clone function). ConfigTools is included in the delivery<\/p>\n<p style=\"font-family: Futura; font-size: 16px; color: #003f81;\">ConfigTools functions for MSX-E3011:<\/p>\n<ul style=\"font-family: Futura; font-size: 16px;\">\n<li>Change of IP address<\/li>\n<li>Display of web interface<\/li>\n<li>Firmware update<\/li>\n<li>Save\/load system configuration<\/li>\n<li>Save\/load channel configuration<\/li>\n<li>Monitor for analog inputs<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p style=\"font-family: Futura; font-size: 16px;\">The\u00a0<strong>Ethernet system for temperature measurement MSX-E3211<\/strong>\u00a0has\u00a0<strong>16\/8\/4 differential inputs<\/strong>, 24 bit,\u00a0<strong>for thermocouples or RTD (Pt100, Pt1000)<\/strong>. Up to 8 channels can be acquired simultaneously. The system was developped for fast measurement directly at the sensor in the\u00a0<strong>harsh industrial environment<\/strong>. It has a robust normed metal housing with the\u00a0<strong>degree of protection IP 65\u00a0<\/strong>and an extended temperature range from\u00a0<strong>-40\u00b0C to +85\u00b0C<\/strong>. The ARM\u00ae9 32-bit processor allows the calculation of the acquired values. The Development Mode allows to customise applications individually. Through synchro connection, several MSX-E systems can be daisy-chained and synchronised with one another in the \u00b5s range.<\/p>\n[su_button url=\"https:\/\/www.addi-data.com\/formproduct?product_page=MSX-E3211\" style=\"glass\" background=\"#9b2e41\" size=\"5\" icon=\"icon: tags\" icon_color=\"#ffffff\" text_shadow=\"0px 0px 0px #000000\"]Get a quote[\/su_button]\n","protected":false},"featured_media":3857,"template":"","meta":{"content-type":""},"product_brand":[],"product_cat":[174],"product_tag":[],"class_list":["post-1285","product","type-product","status-publish","has-post-thumbnail","product_cat-msx-e-system-temperature-measurement","first","instock","shipping-taxable","product-type-simple","prodpage-classic"],"yoast_head":"\n<title>MSX-E3211 - Fieldbus DAQ System - Temperature measurement<\/title>\n<meta name=\"description\" content=\"The\u00a0Ethernet system for temperature measurement MSX-E3211\u00a0has\u00a016\/8\/4 differential inputs, 24 bit,\u00a0for thermocouples or RTD (Pt100, Pt1000).\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.addi-data.com\/pl\/product\/msx-e3211\/\" \/>\n<meta property=\"og:locale\" content=\"pl_PL\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"MSX-E3211 - Fieldbus DAQ System - Temperature measurement\" \/>\n<meta property=\"og:description\" content=\"The\u00a0Ethernet system for temperature measurement MSX-E3211\u00a0has\u00a016\/8\/4 differential inputs, 24 bit,\u00a0for thermocouples or RTD (Pt100, Pt1000).\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.addi-data.com\/pl\/product\/msx-e3211\/\" \/>\n<meta property=\"og:site_name\" content=\"ADDI-DATA\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-16T07:21:02+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.addi-data.com\/wp-content\/uploads\/2022\/07\/MSX-E3211-D_schwarzes-Gehause_4c.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1063\" \/>\n\t<meta property=\"og:image:height\" content=\"832\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Szacowany czas czytania\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minuta\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.addi-data.com\\\/product\\\/msx-e3211\",\"url\":\"https:\\\/\\\/www.addi-data.com\\\/product\\\/msx-e3211\",\"name\":\"MSX-E3211 - Fieldbus DAQ System - Temperature measurement\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.addi-data.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.addi-data.com\\\/product\\\/msx-e3211#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.addi-data.com\\\/product\\\/msx-e3211#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.addi-data.com\\\/wp-content\\\/uploads\\\/2022\\\/07\\\/MSX-E3211-D_schwarzes-Gehause_4c.png\",\"datePublished\":\"2022-07-29T07:05:49+00:00\",\"dateModified\":\"2026-04-16T07:21:02+00:00\",\"description\":\"The\u00a0Ethernet system for temperature measurement MSX-E3211\u00a0has\u00a016\\\/8\\\/4 differential inputs, 24 bit,\u00a0for thermocouples or RTD (Pt100, Pt1000).\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.addi-data.com\\\/product\\\/msx-e3211#breadcrumb\"},\"inLanguage\":\"pl-PL\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.addi-data.com\\\/product\\\/msx-e3211\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"pl-PL\",\"@id\":\"https:\\\/\\\/www.addi-data.com\\\/product\\\/msx-e3211#primaryimage\",\"url\":\"https:\\\/\\\/www.addi-data.com\\\/wp-content\\\/uploads\\\/2022\\\/07\\\/MSX-E3211-D_schwarzes-Gehause_4c.png\",\"contentUrl\":\"https:\\\/\\\/www.addi-data.com\\\/wp-content\\\/uploads\\\/2022\\\/07\\\/MSX-E3211-D_schwarzes-Gehause_4c.png\",\"width\":1063,\"height\":832,\"caption\":\"MSX-E3211 fieldbus system\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.addi-data.com\\\/product\\\/msx-e3211#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.addi-data.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\\\/\\\/www.addi-data.com\\\/test\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"MSX-E3211 &#8211; Fieldbus DAQ System &#8211; Temperature measurement\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.addi-data.com\\\/#website\",\"url\":\"https:\\\/\\\/www.addi-data.com\\\/\",\"name\":\"ADDI-DATA\",\"description\":\"Discover powerful high-tech products for industrial measurement and automation.\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.addi-data.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.addi-data.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"pl-PL\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.addi-data.com\\\/#organization\",\"name\":\"ADDI-DATA\",\"url\":\"https:\\\/\\\/www.addi-data.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pl-PL\",\"@id\":\"https:\\\/\\\/www.addi-data.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www3.addi-data.com\\\/wp-content\\\/uploads\\\/2022\\\/05\\\/addi_data_spirit_of_excellence_PETIT_COULEURS_2021.png\",\"contentUrl\":\"https:\\\/\\\/www3.addi-data.com\\\/wp-content\\\/uploads\\\/2022\\\/05\\\/addi_data_spirit_of_excellence_PETIT_COULEURS_2021.png\",\"width\":786,\"height\":211,\"caption\":\"ADDI-DATA\"},\"image\":{\"@id\":\"https:\\\/\\\/www.addi-data.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/addi-data\\\/\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCM2yhuO7z5Jpe9KRgg8HsRw\\\/videos\"]}]}<\/script>\n","yoast_head_json":{"title":"MSX-E3211 - Fieldbus DAQ System - Temperature measurement","description":"The\u00a0Ethernet system for temperature measurement MSX-E3211\u00a0has\u00a016\/8\/4 differential inputs, 24 bit,\u00a0for thermocouples or RTD (Pt100, Pt1000).","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.addi-data.com\/pl\/product\/msx-e3211\/","og_locale":"pl_PL","og_type":"article","og_title":"MSX-E3211 - Fieldbus DAQ System - Temperature measurement","og_description":"The\u00a0Ethernet system for temperature measurement MSX-E3211\u00a0has\u00a016\/8\/4 differential inputs, 24 bit,\u00a0for thermocouples or RTD (Pt100, Pt1000).","og_url":"https:\/\/www.addi-data.com\/pl\/product\/msx-e3211\/","og_site_name":"ADDI-DATA","article_modified_time":"2026-04-16T07:21:02+00:00","og_image":[{"width":1063,"height":832,"url":"https:\/\/www.addi-data.com\/wp-content\/uploads\/2022\/07\/MSX-E3211-D_schwarzes-Gehause_4c.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Szacowany czas czytania":"1 minuta"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.addi-data.com\/product\/msx-e3211","url":"https:\/\/www.addi-data.com\/product\/msx-e3211","name":"MSX-E3211 - Fieldbus DAQ System - Temperature measurement","isPartOf":{"@id":"https:\/\/www.addi-data.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.addi-data.com\/product\/msx-e3211#primaryimage"},"image":{"@id":"https:\/\/www.addi-data.com\/product\/msx-e3211#primaryimage"},"thumbnailUrl":"https:\/\/www.addi-data.com\/wp-content\/uploads\/2022\/07\/MSX-E3211-D_schwarzes-Gehause_4c.png","datePublished":"2022-07-29T07:05:49+00:00","dateModified":"2026-04-16T07:21:02+00:00","description":"The\u00a0Ethernet system for temperature measurement MSX-E3211\u00a0has\u00a016\/8\/4 differential inputs, 24 bit,\u00a0for thermocouples or RTD (Pt100, Pt1000).","breadcrumb":{"@id":"https:\/\/www.addi-data.com\/product\/msx-e3211#breadcrumb"},"inLanguage":"pl-PL","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.addi-data.com\/product\/msx-e3211"]}]},{"@type":"ImageObject","inLanguage":"pl-PL","@id":"https:\/\/www.addi-data.com\/product\/msx-e3211#primaryimage","url":"https:\/\/www.addi-data.com\/wp-content\/uploads\/2022\/07\/MSX-E3211-D_schwarzes-Gehause_4c.png","contentUrl":"https:\/\/www.addi-data.com\/wp-content\/uploads\/2022\/07\/MSX-E3211-D_schwarzes-Gehause_4c.png","width":1063,"height":832,"caption":"MSX-E3211 fieldbus system"},{"@type":"BreadcrumbList","@id":"https:\/\/www.addi-data.com\/product\/msx-e3211#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.addi-data.com\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/www.addi-data.com\/test"},{"@type":"ListItem","position":3,"name":"MSX-E3211 &#8211; Fieldbus DAQ System &#8211; Temperature measurement"}]},{"@type":"WebSite","@id":"https:\/\/www.addi-data.com\/#website","url":"https:\/\/www.addi-data.com\/","name":"ADDI-DATA","description":"Discover powerful high-tech products for industrial measurement and automation.","publisher":{"@id":"https:\/\/www.addi-data.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.addi-data.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pl-PL"},{"@type":"Organization","@id":"https:\/\/www.addi-data.com\/#organization","name":"ADDI-DATA","url":"https:\/\/www.addi-data.com\/","logo":{"@type":"ImageObject","inLanguage":"pl-PL","@id":"https:\/\/www.addi-data.com\/#\/schema\/logo\/image\/","url":"https:\/\/www3.addi-data.com\/wp-content\/uploads\/2022\/05\/addi_data_spirit_of_excellence_PETIT_COULEURS_2021.png","contentUrl":"https:\/\/www3.addi-data.com\/wp-content\/uploads\/2022\/05\/addi_data_spirit_of_excellence_PETIT_COULEURS_2021.png","width":786,"height":211,"caption":"ADDI-DATA"},"image":{"@id":"https:\/\/www.addi-data.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/addi-data\/","https:\/\/www.youtube.com\/channel\/UCM2yhuO7z5Jpe9KRgg8HsRw\/videos"]}]}},"_links":{"self":[{"href":"https:\/\/www.addi-data.com\/pl\/wp-json\/wp\/v2\/product\/1285","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.addi-data.com\/pl\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.addi-data.com\/pl\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.addi-data.com\/pl\/wp-json\/wp\/v2\/media\/3857"}],"wp:attachment":[{"href":"https:\/\/www.addi-data.com\/pl\/wp-json\/wp\/v2\/media?parent=1285"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.addi-data.com\/pl\/wp-json\/wp\/v2\/product_brand?post=1285"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.addi-data.com\/pl\/wp-json\/wp\/v2\/product_cat?post=1285"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.addi-data.com\/pl\/wp-json\/wp\/v2\/product_tag?post=1285"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}<!-- This website is optimized by Airlift. Learn more: https://airlift.net. Template:. Learn more: https://airlift.net. Template: 6a1da9131906363e1d0290a4. Config Timestamp: 2026-06-01 15:45:22 UTC, Cached Timestamp: 2026-06-14 04:37:03 UTC -->