{"id":1287,"date":"2022-07-29T07:12:06","date_gmt":"2022-07-29T07:12:06","guid":{"rendered":"https:\/\/www3.addi-data.com\/?post_type=product&p=1287"},"modified":"2026-04-16T07:22:45","modified_gmt":"2026-04-16T07:22:45","slug":"msx-e3601","status":"publish","type":"product","link":"https:\/\/www.addi-data.com\/pl\/product\/msx-e3601","title":{"rendered":"
Features<\/p>\n
Analog inputs<\/p>\n
Current sources<\/p>\n
Safety features<\/p>\n
Interfaces<\/p>\n
Communication interfaces<\/p>\n
Synchronisation\/time stamp<\/p>\n
Time stamp<\/p>\n
Several MSX-E systems can be synchronised with one another in the \u00b5s range through a synchro connection. This allows to start a synchronous data acquisition, to
\r\ngenerate trigger events and to synchronise the time on several MSX-E systems. Furthermore, the systems have a time stamp that logs the point in time at which the data was acquired by the system.<\/p>\n
The combination of synchronisation and time stamp (TS) allows the clear allocation of signals that were captured by several systems.<\/p>\n
Acquisition modes<\/p>\n
Sequence mode<\/p>\n
In sequence mode, a list of channels is acquired. Thereby, the single measurement rows are stored one after another. The client receives the acquired values asynchronously to the acquisition through a socket connection. In the sequence mode, the measurement values are read in chronological order, this means the oldest values are read first. The acquisition can be effected continuously, with or without delay or in combination with a hardware or synchro trigger<\/p>\n
Onboard programming \/ stand-alone operation<\/p>\n
Development mode<\/p>\n
With the Development mode of the MSX-E systems you can customise your measurement, control and regulation applications to fit your requirements. The programs run directly on the MSX-E systems, which has two advantages: external PCs are relieved and you can process data freely according to your requirements. This helps you to improve the efficiency of your processes and to secure your investments.<\/p>\n
Anti-aliasing filter<\/p>\n
Low-pass filters are used before or during digitising in order to remove all frequency components which are higher than the Nyquist frequency. This is to make sure that the digitised value or result does not contain any unwanted frequencies (aliasing frequencies). According to the Nyquist criterion, in order to obtain the full signal information, the sampling rate must be at least 2 x the signal band width.<\/p>\n
Firmware and software adaptation<\/p>\n
Because MSX-E systems are very flexible, the MSX-E3601 firmware can be easily extended. Thus, calculations such as RMS or limit values etc. can be
\r\nintegrated. Using the Development Mode, it is possible to create self-sufficient intelligent nodes.<\/p>\n
ConfigTools<\/p>\n
The ConfigTools program allows an easy administration of the MSX-E systems. These are automatically detected in the network. ConfigTools
\r\nconsists of common and specific functions. In addition, with ConfigTools, the complete configuration of a MSX-E system can be saved and transferred to another system of the same type (clone function). ConfigTools is included in the delivery<\/p>\n
ConfigTools functions for MSX-E3011:<\/p>\n
The\u00a0Ethernet system for noise vibration measurement MSX-E3601<\/strong>\u00a0is available in 2 versions:\u00a0MSX-E3601<\/strong>\u00a0with\u00a08 SE\/diff. inputs<\/strong>\u00a0and\u00a08 current sources for ICP\u00ae-\/IEPE-sensors<\/strong>\u00a0or\u00a0MSX-E3601-2\u00a0<\/strong>with\u00a02 SE\/diff. inputs<\/strong>\u00a0and\u00a02 current sources for ICP\u00ae-\/IEPE-sensors.\u00a0<\/strong>All analog inputs can be acquired simultaneously. The system was developed for the acquisition of dynamic signals in the harsh industrial environment and thus has a robust normed metal housing with the\u00a0degree of protection IP 65\u00a0<\/strong>and an extended temperature range from\u00a0-40\u00b0C to +85\u00b0C<\/strong>. The ARM\u00ae9 32-bit processor allows the calculation of the acquired values. The Development Mode allows to customise applications individually. Through synchro connection, several MSX-E systems can be cascaed and synchronised with one another in the \u00b5s range.<\/p>\n[su_button url=\"https:\/\/www.addi-data.com\/formproduct?product_page=MSX-E3601\" style=\"glass\" background=\"#9b2e41\" size=\"5\" icon=\"icon: tags\" icon_color=\"#ffffff\" text_shadow=\"0px 0px 0px #000000\"]Get a quote[\/su_button]\n","protected":false},"featured_media":1023,"template":"","meta":{"content-type":""},"product_brand":[],"product_cat":[176],"product_tag":[],"class_list":["post-1287","product","type-product","status-publish","has-post-thumbnail","product_cat-msx-e-system-vibration-measurement","first","instock","shipping-taxable","product-type-simple","prodpage-classic"],"yoast_head":"\n