{"id":1300,"date":"2022-07-29T08:05:38","date_gmt":"2022-07-29T08:05:38","guid":{"rendered":"https:\/\/www3.addi-data.com\/?post_type=product&#038;p=1300"},"modified":"2026-04-16T07:38:11","modified_gmt":"2026-04-16T07:38:11","slug":"msx-e3711","status":"publish","type":"product","link":"https:\/\/www.addi-data.com\/pl\/product\/msx-e3711","title":{"rendered":"<h1 style=\"font-family: Futura; font-size: 26px;\">MSX-E3711 &#8211; Fieldbus DAQ System &#8211; Length measurement<\/h1>"},"content":{"rendered":"<p style=\"font-family: Futura; font-size: 26px; color: #003f81;\">Features<\/p>\n<ul style=\"font-family: Futura; font-size: 16px;\">\n<li>ARM\u00ae9 32-bit processor<\/li>\n<li>Robust standardized metal housing<\/li>\n<li>Power Save Mode: Reduced power consumption when no acquisition runs<\/li>\n<\/ul>\n<p style=\"font-family: Futura; font-size: 16px; color: #003f81;\">Transducer inputs<\/p>\n<ul style=\"font-family: Futura; font-size: 16px;\">\n<li>8 transducer inputs, 24-bit, 5-pin M18 female connector<\/li>\n<li>Half-bridge (HB), LVDT, Mahr-compatible, Knaebel<\/li>\n<li>Diagnostics at short-circuits or \u00adline break<\/li>\n<li>Simultaneous acquisition<\/li>\n<\/ul>\n<p style=\"font-family: Futura; font-size: 16px; color: #003f81;\">Counter inputs<\/p>\n<ul style=\"font-family: Futura; font-size: 16px;\">\n<li>1 x 32-bit incremental counter input, max. 5 MHz<\/li>\n<li>Voltage supply of sensors with M23 female connector (24 V or 5 V)<\/li>\n<li>Single, double, quadruple edge analysis<\/li>\n<li>Compare logic<\/li>\n<\/ul>\n<p style=\"font-family: Futura; font-size: 16px; color: #003f81;\">Temperature input<\/p>\n<ul style=\"font-family: Futura; font-size: 16px;\">\n<li>1 x RTD input, 16-bit, 5-pin M12 female connector<\/li>\n<li>+\/- 0,01 \u00b0C resolution<\/li>\n<li>Thermocouple input, optional (MSX-E3711-TC)<\/li>\n<\/ul>\n<p style=\"font-family: Futura; font-size: 16px; color: #003f81;\">Safety features<\/p>\n<ul style=\"font-family: Futura; font-size: 16px;\">\n<li>Status LEDs for fast error diagnostics<\/li>\n<li>Optical isolation<\/li>\n<li>Input filters<\/li>\n<li>Overvoltage protection \u00b1 40 V<\/li>\n<li>Internal temperature monitoring<\/li>\n<\/ul>\n<p style=\"font-family: Futura; font-size: 26px; color: #003f81;\">Interfaces<\/p>\n<ul style=\"font-family: Futura; font-size: 16px;\">\n<li>Fast 24 V trigger input<\/li>\n<li>Ethernet switch with 2 ports<\/li>\n<li>Synchronisation\/trigger In\/Out<\/li>\n<li>Line in for 24 V supply and cascading<\/li>\n<\/ul>\n<p style=\"font-family: Futura; font-size: 16px; color: #003f81;\">Communication interfaces<\/p>\n<ul style=\"font-family: Futura; font-size: 16px;\">\n<li>Web server (configuration and monitoring)<\/li>\n<li>Command server SOAP for transferring commands<\/li>\n<li>Data server (TCP\/IP or UDP socket) for sending acquisition data<\/li>\n<li>Event server (TCP\/IP socket) for sending system events (Diagnostics such as temperature, short-circuits &#8230;)<\/li>\n<li>Command server Modbus TCP and Modbus (UDP) for sending commands<\/li>\n<\/ul>\n<p style=\"font-family: Futura; font-size: 26px; color: #003f81;\">Synchronisation\/time stamp<\/p>\n<p style=\"font-family: Futura; font-size: 16px; color: #003f81;\">Time stamp<\/p>\n<p style=\"font-family: Futura; font-size: 16px;\" class=\"translation-block\">Several MSX-E systems can be synchronised with one another in the \u00b5s range through a synchro connection. This allows to start a synchronous data acquisition, to<br>\r\ngenerate trigger events and to synchronise the time on several MSX-E systems. Furthermore, the systems have a time stamp that logs the point in time at which the data was acquired by the system.<\/p>\n<p style=\"font-family: Futura; font-size: 16px;\">The combination of synchronisation and time stamp (TS) allows the clear allocation of signals that were captured by several systems.<\/p>\n<p style=\"font-family: Futura; font-size: 26px; color: #003f81;\">Acquisition modes<\/p>\n<p style=\"font-family: Futura; font-size: 16px; color: #003f81;\">Auto-refresh mode<\/p>\n<p style=\"font-family: Futura; font-size: 16px;\">In the auto-refresh mode, the measurement values are updated automatically after each acquisition. The acquisition is initialised once and the values of the channels are stored in the memory of the MSX-E Ethernet system. The client (e.g. PC, server, PLC, \u2026) reads the acquired values asynchronously to the acquisition through socket connection, SOAP or Modbus function. Thereby, the new value is read and the old values are overwritten. In addition to the measurement values, the auto-refresh counter can also be read, which allows to sort the measurement values chronologically. The auto-refresh mode can be combined with a hardware or a synchro trigger and also allows the automatic averaging of values.<\/p>\n<p style=\"font-family: Futura; font-size: 16px; color: #003f81;\">Sequence Mode<\/p>\n<p style=\"font-family: Futura; font-size: 16px;\">In the sequence mode, a list of channels is acquired. Thereby, the single measurement rows are stored one after another. The client receives the acquired values asynchronously to the acquisition through a socket connection. In the sequence mode, the measurement values are read in chronological order, this means the oldest values are read first. The acquisition can be effected continuously, with or without delay or in combination with a hardware or synchro trigger.<\/p>\n<p style=\"font-family: Futura; font-size: 16px; color: #003f81;\">Compare logic<\/p>\n<p style=\"font-family: Futura; font-size: 16px;\">With the compare logic of the incremental counter, a synchro-trigger signal can be generated in order to latch the counter value, the transducers and the temperature input as soon as the counter value is equal to the compare value. Thus all the inputs of the MSX-E3711 system can be acquired simultaneously. With the additional \u201eModulo-Mode\u201c (Modulo Compare), a trigger can also be generated at the n value of the compare value. Thus it is possible, e. g. when using an encoder with 3,600 steps \/ revolution to obtain each degree of a measurement value (Modulo Compare = 10). The thus generated synchro-trigger can also be used for data acquisition on further MSX-E systems.<\/p>\n<p style=\"font-family: Futura; font-size: 26px; color: #003f81;\">Onboard programming \/ stand-alone operation<\/p>\n<p style=\"font-family: Futura; font-size: 16px; color: #003f81;\">Development mode<\/p>\n<p style=\"font-family: Futura; font-size: 16px;\">With the Development mode of the MSX-E systems you can customise your measurement, control and regulation applications to fit your requirements. The programs run directly on the MSX-E systems, which has two advantages: external PCs are relieved and you can process data freely according to your requirements. This helps you to improve the efficiency of your processes and to secure your investments.<\/p>\n<p style=\"font-family: Futura; font-size: 26px; color: #003f81;\">ConfigTools<\/p>\n<p style=\"font-family: Futura; font-size: 16px;\" class=\"translation-block\">The ConfigTools program allows an easy administration of the MSX-E systems. These are automatically detected in the network. ConfigTools<br>\r\nconsists of common and specific functions. In addition, with ConfigTools, the complete configuration of a MSX-E system can be saved and transferred to another system of the same type (clone function). ConfigTools is included in the delivery<\/p>\n<p style=\"font-family: Futura; font-size: 16px; color: #003f81;\">ConfigTools functions for MSX-E3011:<\/p>\n<ul style=\"font-family: Futura; font-size: 16px;\">\n<li>Change of IP address<\/li>\n<li>Display of web interface<\/li>\n<li>Firmware update<\/li>\n<li>Save\/load system configuration<\/li>\n<li>Save\/load channel configuration<\/li>\n<li>Monitor for analog inputs<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p style=\"font-family: Futura; font-size: 16px;\">The\u00a0<strong>Ethernet system for length measurement MSX-E3711<\/strong>\u00a0has\u00a0<strong>8 inputs for inductive displacement transducers<\/strong>\u00a0(Half-Bridge, LVDT, Mahr or Kn\u00e4bel),<strong>\u00a01 incremental counter input\u00a0<\/strong>and<strong>\u00a01 input for temperature measurement\u00a0<\/strong>(Pt100) or thermocouples (TC). The system was developed for the simultaneous measurement and acquisition of length, temperature and position reference in the\u00a0<strong>harsh industrial environment<\/strong>. It has a robust normed metal housing with the\u00a0<strong>degree of protection IP 65\u00a0<\/strong>and an extended temperature range from\u00a0<strong>-40\u00b0C to +85\u00b0C<\/strong>. The ARM\u00ae9 32-bit processor allows the calculation of the acquired values. The Development Mode allows to customise applications individually. Through synchro connection, several MSX-E systems can be daisy-chained and synchronised with one another in the \u00b5s range.<\/p>\n[su_button url=\"https:\/\/www.addi-data.com\/formproduct?product_page=MSX-E3711\" style=\"glass\" background=\"#9b2e41\" size=\"5\" icon=\"icon: tags\" icon_color=\"#ffffff\" text_shadow=\"0px 0px 0px #000000\"]Get a quote[\/su_button]\n","protected":false},"featured_media":1043,"template":"","meta":{"content-type":""},"product_brand":[],"product_cat":[179],"product_tag":[],"class_list":["post-1300","product","type-product","status-publish","has-post-thumbnail","product_cat-msx-e-system-length-measurement","first","instock","shipping-taxable","product-type-simple","prodpage-classic"],"yoast_head":"\n<title>MSX-E3711 - Fieldbus DAQ System - Length measurement - ADDI-DATA<\/title>\n<meta name=\"description\" content=\"The MSX-E3711 Ethernet system for inductive probes acquires the values of up to 8 LVDT, half-bridge, Mahr or Kn\u00e4bel sensors simultaneously with 24-bit resolution.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.addi-data.com\/pl\/product\/msx-e3711\/\" \/>\n<meta property=\"og:locale\" content=\"pl_PL\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"MSX-E3711 - Fieldbus DAQ System - Length measurement - ADDI-DATA\" \/>\n<meta property=\"og:description\" content=\"The MSX-E3711 Ethernet system for inductive probes acquires the values of up to 8 LVDT, half-bridge, Mahr or Kn\u00e4bel sensors simultaneously with 24-bit resolution.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.addi-data.com\/pl\/product\/msx-e3711\/\" \/>\n<meta property=\"og:site_name\" content=\"ADDI-DATA\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-16T07:38:11+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.addi-data.com\/wp-content\/uploads\/2022\/07\/MSX-E3711_h252.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"300\" \/>\n\t<meta property=\"og:image:height\" content=\"252\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Szacowany czas czytania\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minuta\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.addi-data.com\\\/product\\\/msx-e3711\",\"url\":\"https:\\\/\\\/www.addi-data.com\\\/product\\\/msx-e3711\",\"name\":\"MSX-E3711 - Fieldbus DAQ System - Length measurement - ADDI-DATA\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.addi-data.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.addi-data.com\\\/product\\\/msx-e3711#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.addi-data.com\\\/product\\\/msx-e3711#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.addi-data.com\\\/wp-content\\\/uploads\\\/2022\\\/07\\\/MSX-E3711_h252.jpg\",\"datePublished\":\"2022-07-29T08:05:38+00:00\",\"dateModified\":\"2026-04-16T07:38:11+00:00\",\"description\":\"The MSX-E3711 Ethernet system for inductive probes acquires the values of up to 8 LVDT, half-bridge, Mahr or Kn\u00e4bel sensors simultaneously with 24-bit resolution.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.addi-data.com\\\/product\\\/msx-e3711#breadcrumb\"},\"inLanguage\":\"pl-PL\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.addi-data.com\\\/product\\\/msx-e3711\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"pl-PL\",\"@id\":\"https:\\\/\\\/www.addi-data.com\\\/product\\\/msx-e3711#primaryimage\",\"url\":\"https:\\\/\\\/www.addi-data.com\\\/wp-content\\\/uploads\\\/2022\\\/07\\\/MSX-E3711_h252.jpg\",\"contentUrl\":\"https:\\\/\\\/www.addi-data.com\\\/wp-content\\\/uploads\\\/2022\\\/07\\\/MSX-E3711_h252.jpg\",\"width\":300,\"height\":252,\"caption\":\"MSX-E3711 Length Fieldbus systems\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.addi-data.com\\\/product\\\/msx-e3711#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.addi-data.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\\\/\\\/www.addi-data.com\\\/test\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"MSX-E3711 &#8211; Fieldbus DAQ System &#8211; Length measurement\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.addi-data.com\\\/#website\",\"url\":\"https:\\\/\\\/www.addi-data.com\\\/\",\"name\":\"ADDI-DATA\",\"description\":\"Discover powerful high-tech products for industrial measurement and automation.\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.addi-data.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.addi-data.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"pl-PL\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.addi-data.com\\\/#organization\",\"name\":\"ADDI-DATA\",\"url\":\"https:\\\/\\\/www.addi-data.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pl-PL\",\"@id\":\"https:\\\/\\\/www.addi-data.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www3.addi-data.com\\\/wp-content\\\/uploads\\\/2022\\\/05\\\/addi_data_spirit_of_excellence_PETIT_COULEURS_2021.png\",\"contentUrl\":\"https:\\\/\\\/www3.addi-data.com\\\/wp-content\\\/uploads\\\/2022\\\/05\\\/addi_data_spirit_of_excellence_PETIT_COULEURS_2021.png\",\"width\":786,\"height\":211,\"caption\":\"ADDI-DATA\"},\"image\":{\"@id\":\"https:\\\/\\\/www.addi-data.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/addi-data\\\/\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCM2yhuO7z5Jpe9KRgg8HsRw\\\/videos\"]}]}<\/script>\n","yoast_head_json":{"title":"MSX-E3711 - Fieldbus DAQ System - Length measurement - ADDI-DATA","description":"The MSX-E3711 Ethernet system for inductive probes acquires the values of up to 8 LVDT, half-bridge, Mahr or Kn\u00e4bel sensors simultaneously with 24-bit resolution.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.addi-data.com\/pl\/product\/msx-e3711\/","og_locale":"pl_PL","og_type":"article","og_title":"MSX-E3711 - Fieldbus DAQ System - Length measurement - ADDI-DATA","og_description":"The MSX-E3711 Ethernet system for inductive probes acquires the values of up to 8 LVDT, half-bridge, Mahr or Kn\u00e4bel sensors simultaneously with 24-bit resolution.","og_url":"https:\/\/www.addi-data.com\/pl\/product\/msx-e3711\/","og_site_name":"ADDI-DATA","article_modified_time":"2026-04-16T07:38:11+00:00","og_image":[{"width":300,"height":252,"url":"https:\/\/www.addi-data.com\/wp-content\/uploads\/2022\/07\/MSX-E3711_h252.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Szacowany czas czytania":"1 minuta"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.addi-data.com\/product\/msx-e3711","url":"https:\/\/www.addi-data.com\/product\/msx-e3711","name":"MSX-E3711 - Fieldbus DAQ System - Length measurement - ADDI-DATA","isPartOf":{"@id":"https:\/\/www.addi-data.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.addi-data.com\/product\/msx-e3711#primaryimage"},"image":{"@id":"https:\/\/www.addi-data.com\/product\/msx-e3711#primaryimage"},"thumbnailUrl":"https:\/\/www.addi-data.com\/wp-content\/uploads\/2022\/07\/MSX-E3711_h252.jpg","datePublished":"2022-07-29T08:05:38+00:00","dateModified":"2026-04-16T07:38:11+00:00","description":"The MSX-E3711 Ethernet system for inductive probes acquires the values of up to 8 LVDT, half-bridge, Mahr or Kn\u00e4bel sensors simultaneously with 24-bit resolution.","breadcrumb":{"@id":"https:\/\/www.addi-data.com\/product\/msx-e3711#breadcrumb"},"inLanguage":"pl-PL","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.addi-data.com\/product\/msx-e3711"]}]},{"@type":"ImageObject","inLanguage":"pl-PL","@id":"https:\/\/www.addi-data.com\/product\/msx-e3711#primaryimage","url":"https:\/\/www.addi-data.com\/wp-content\/uploads\/2022\/07\/MSX-E3711_h252.jpg","contentUrl":"https:\/\/www.addi-data.com\/wp-content\/uploads\/2022\/07\/MSX-E3711_h252.jpg","width":300,"height":252,"caption":"MSX-E3711 Length Fieldbus systems"},{"@type":"BreadcrumbList","@id":"https:\/\/www.addi-data.com\/product\/msx-e3711#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.addi-data.com\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/www.addi-data.com\/test"},{"@type":"ListItem","position":3,"name":"MSX-E3711 &#8211; Fieldbus DAQ System &#8211; Length measurement"}]},{"@type":"WebSite","@id":"https:\/\/www.addi-data.com\/#website","url":"https:\/\/www.addi-data.com\/","name":"ADDI-DATA","description":"Discover powerful high-tech products for industrial measurement and automation.","publisher":{"@id":"https:\/\/www.addi-data.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.addi-data.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pl-PL"},{"@type":"Organization","@id":"https:\/\/www.addi-data.com\/#organization","name":"ADDI-DATA","url":"https:\/\/www.addi-data.com\/","logo":{"@type":"ImageObject","inLanguage":"pl-PL","@id":"https:\/\/www.addi-data.com\/#\/schema\/logo\/image\/","url":"https:\/\/www3.addi-data.com\/wp-content\/uploads\/2022\/05\/addi_data_spirit_of_excellence_PETIT_COULEURS_2021.png","contentUrl":"https:\/\/www3.addi-data.com\/wp-content\/uploads\/2022\/05\/addi_data_spirit_of_excellence_PETIT_COULEURS_2021.png","width":786,"height":211,"caption":"ADDI-DATA"},"image":{"@id":"https:\/\/www.addi-data.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/addi-data\/","https:\/\/www.youtube.com\/channel\/UCM2yhuO7z5Jpe9KRgg8HsRw\/videos"]}]}},"_links":{"self":[{"href":"https:\/\/www.addi-data.com\/pl\/wp-json\/wp\/v2\/product\/1300","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.addi-data.com\/pl\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.addi-data.com\/pl\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.addi-data.com\/pl\/wp-json\/wp\/v2\/media\/1043"}],"wp:attachment":[{"href":"https:\/\/www.addi-data.com\/pl\/wp-json\/wp\/v2\/media?parent=1300"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.addi-data.com\/pl\/wp-json\/wp\/v2\/product_brand?post=1300"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.addi-data.com\/pl\/wp-json\/wp\/v2\/product_cat?post=1300"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.addi-data.com\/pl\/wp-json\/wp\/v2\/product_tag?post=1300"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}<!-- This website is optimized by Airlift. Learn more: https://airlift.net. Template:. Learn more: https://airlift.net. Template: 6a1da9131906363e1d0290a4. Config Timestamp: 2026-06-01 15:45:22 UTC, Cached Timestamp: 2026-06-14 04:37:02 UTC -->