CPCI-3001 – DAQ card Analog inputs

The CompactPCI analog input card CPCI-3001 has 16/8/4 SE or 8/4 differential inputs, 12 bit, with a throughput rate of 100 kHz. Futhermore, it has 8 digital I/O and 2 timers.  The card is especially suited for applications in the sector of industrial process control, measurement technology and monitoring, for example for multichannel data acquisition, for the control of chemical processes, for the acquisition of sensor data etc.

NEW: The CPCI-3001 is now operating in the  extended temperature range -40°C to +85°C

 

Description

Features

  • Can be inserted in PXI systems, with restricted functionality
  • Monitoring program for testing and setting the board functions

Analog inputs:

  • 16 single-ended/8 differential inputs or 8 single-ended/4 differential inputs or 4 single-ended inputs
  • 12-bit resolution
  • Throughput: 100 kHz
  • Input voltage: 0-10 V, ± 10 V, 0-5 V, ± 5 V, 0-2 V, ± 2 V, 0-1 V, ±1 V, 0-20 mA (option) freely programmable through software for each channel
  • Gain PGA x1, x2, x5, x10 freely programmable through software for each channel
  • PCI DMA for analog data acquisition

Analog acquisition:

  • One single channel, several channels, several channels through scan list
  • Automatic analog acquisition through cyclic timer control
  • Acquisition through scan list: up to 16 entries with gain, channel, unipolar/bipolar
  • Acquisition triggered through software, timer, external event
  • Trigger functions: Software trigger or external trigger: the analog acquisition (single or sequence) is started through signal switching from 0 V to 24 V at the digital input 0.
  • Interrupt: end of single channel, end of multichannel,
    end of scan list

Digital

  • 4 digital inputs, 24 V, optically isolated
  • 4 digital outputs, 24 V, optically isolated

Timer

  • 24-bit
  • Timer 2 as cyclic time counter

Safety features

  • Optical isolation 500 V min
  • Timer 2 as cyclic time counter
  • Overvoltage protection ± 40 V, analog inputs
  • Protection against overvoltage (±30 V) and high-frequency EMI
  • Input filters: 159 kHz
  • Noise neutralisation of the PC supply

Applications

  • Industrial process control
  • Industrial measurement and monitoring
  • Multichannel data acquisition
  • Control of chemical processes
  • Factory automation
  • Acquisition of sensor data, current measurement
  • Laboratory equipment, instrumentation
  • Current measurement
  • Instrumentation

Software

Calibration tool (Option CAL3120): Do the fine adjustment fast and reliably and save the generated calibration report file. All you need is a highly precise calibration source and a precise digital multimeter (not included in the delivery content)

Standard drivers for:

  • Linux
  • 32-bit drivers for Windows 8 / 7 / Vista / XP / 2000
  • Signed 64-bit drivers for Windows 8 / 7 / XP
  • Real-time use with Linux and Windows on request

Drivers and samples for the following compilers and software packages:

  • Microsoft VC++ • Microsoft C
  • Borland C++ • Borland C
  • Visual Basic • Delphi • Turbo Pascal
  •  LabVIEW • DASYLab • DIAdem

On request:

Further operating systems, compilers and samples. Driver download: www.addi-data.com/downloads

ACCESSORIES

Accessories for DAQ cards

Find all the necessary and compatible accessories right here

DOWNLOADS

Drivers

64-bit drivers for Windows and drivers for Linux as well as programming samples are included.
Real-time drivers for Linux and Windows are available on request.

For Windows For Linux

 

Datasheets

English version French version German version

 

Manuals

English version


GREEN for the new products
ORANGE for products in end of life

TOP