APCI-3010 – DAQ PCI Card – Analog Inputs
The PCI analog input cards APCI-3010 have 16 SE or 8 differential inputs, 12 bit, and 200 kHz throughput. Furthermore, the card is equipped with timer/counter, watchdog and 8 digital I/O, 24 V as well as 24 TTL I/O. It is available in 2 versions: APCI-3010 (12 bit resolution) and APCI-3016 (16-bit resolution).The board is especially suited for applications in the sector of industrial process control, measurement technology and monitoring, for example for multichannel data acquisition, for the control of chemical processes, for the acquisition of sensor data, current measurement etc. in the harsh industrial environment.
Description
Features
- PCI 3.3 V or 5 V
Analog inputs
- 16/8/4 SE or 8/4/2 diff. inputs, optically isolated
- Resolution: 12-bit
- Throughput: 200 kHz
- Voltage inputs: 0-10 V, ±10 V, 0-5 V, ±5 V, 0-2 V, ±2 V, 0-1 V, ±1 V, freely programmable through software for each channel
- Current inputs: 0-20 mA (option) can be combined freely with voltage inputs
- Gain PGA x1, x2, x5, x10 freely programmable through software for each channel
Analog acquisition
- Different input modes:
1) Simple mode
2) Scan modes
3) Sequence modes
4) Auto Refresh mode - Trigger functions:
– Software trigger or
– external trigger: the analog acquisition (single or sequence) is started through the signal on digital input 0
from 0 V to 24 V - Onboard FIFO (for 512 Analog values)
- PCI-DMA for analog data acquisition
24 V digital I/O
- 24 V digital I/O enable a high interference distance and a long distance between signal transmitter and data acquisition
- 4 digital inputs, 24 V, optically isolated
- 4 digital outputs, 24 V, optically isolated
TTL I/O
- 24 digital TTL inputs/outputs
- Port1: inputs / Port2: outputs / Port3: I/O
- All I/O are at 5 V through pull-up resistors
- Easy programming through I/O read and write commands
Timer/Counter
- 3 / 3, 16-bit
Watchdog
- 1, 16-bit
Safety features
- For more protection in noisy industrial environment
- Optical isolation 1000 V min.
- Creeping distance IEC 61010-1
- Circuit part of the analog acquisition is separated from the circuit part of the digital function
- Overvoltage protection ± 40 V (analog inputs)
- Protection against high-frequency EMI
- Input filters
- Noise neutralisation of the PC supply
- Connection of the I/O-signals through robust industrystandard 37-pin D-Sub connector
Applications
- Industrial process control
- Industrial measurement and monitoring
- Multichannel data acquisition
- Control of chemical processes
- Factory automation
- Acquisition of sensor data
- Laboratory equipment
- Current measurement
- Instrumentation
Software
Standard drivers and samples for:
- Linux
- Windows (32/64)
- Real-time with Linux (i.e Xenomai) and Windows (i.e RTX) on request
On request:
Further operating systems, compilers and samples. Driver download: www.addi-data.com/downloads
DOWNLOADS
Drivers
64-bit drivers for Windows 11/10/8/7/Vista/XP and Linux as well as programming samples are included, real-time drivers for Windows and Linux are available on request.
For Windows For Linux
Datasheets
English version French version German version
Manuals
English version German versionAPPLICATIONS
Measurement tasks in a coal power plant